U.S. Patent Position Analysis
HalterACorporate & U.S. Market ProfileBPublicly Disclosed Technology ArchitectureCPatent Element MappingDAreas of Technical CorrespondenceEPatent Architecture Elements Not Identif…FEvidence SourcesGAnalytical Summary and Implementation Ev…HOperational Control vs. Emergency Response

Halter — Page C

Patent Element Mapping

13

Publicly disclosed

3

Partial / related

0

Requires investigation

27

Not identified publicly

●Confirmed public evidence◐Partial or indirect public evidence○Not identified in reviewed public materials?Implementation detail required
IDPatent elementLayerStatusEvidence
P01Property boundaryProperty model●HALT-EV-001
P02Multiple defined zonesProperty model●HALT-EV-001 · HALT-EV-002
P03Fixed property featuresProperty model○—
P04Livestock associated with propertyLivestock model●—
P05Livestock associated with zonesLivestock model●HALT-EV-001
P06Multiple distributed sensorsSensors & external data◐—
P07External third-party information sourceSensors & external data○—
P08Live external APISensors & external data○—
P09Livestock locationLivestock model●HALT-EV-001 · HALT-EV-002
P10Livestock movement anomalyEvent determination●—
P11Livestock cessation-of-movement determinationEvent determination●HALT-EV-001
P12Livestock entering another zoneEvent determination●—
P13Missing / lost livestockEvent determination◐—
P14Fixed-feature damageEvent determination○—
P15Water infrastructure anomalyEvent determination○—
P16Wildfire eventEvent determination○—
P17Flood eventEvent determination○—
P18Road-block eventEvent determination○—
P19Earthquake eventEvent determination○—
P20Extreme-weather eventEvent determination○—
P21AI event determinationAI layer○—
P22Machine-learning feedback / trainingAI layer○—
P23Most-likely-event outputAI layer○—
P24Severity scoreSeverity○—
P25Number of livestock consideredSeverity○—
P26Human presence consideredSeverity○—
P27Distance to hazardous fixed feature consideredSeverity○—
P28Available property resource consideredSeverity○—
P29External emergency services consideredSeverity○—
P30Distance / location of emergency service consideredSeverity○—
P31Alert generationAlerts●HALT-EV-001 · HALT-EV-002
P32Severity-based alert levelAlerts○—
P33Digital property visualisationVisualisation●HALT-EV-001 · HALT-EV-002
P34Zones shown in GUIVisualisation●HALT-EV-001
P35Fixed features shown in GUIVisualisation○—
P36Event location displayedVisualisation●—
P37Event type displayedVisualisation◐—
P38Generated remedial recommendationRemedial response○—
P39Recommendation considers event typeRemedial response○—
P40Recommendation considers severityRemedial response○—
P41Recommendation considers property resourcesRemedial response○—
P42Recommendation considers emergency servicesRemedial response○—
P43Satellite / fallback communications embodimentCommunications●HALT-EV-002

Reading rule

Statuses describe reviewed public information only. “Not identified in reviewed public information” does not imply that Halter lacks the capability internally.
← Publicly Disclosed Technology ArchitectureAreas of Technical Correspondence →